Data buffer - Network OWL offline

In the event that the Network OWL looses its Internet connection it can buffer some 12,415 logs in total. So long as the Internet connection is restored before this buffer becomes full then no data will be lost - the Network OWL will automatically upload buffered data when connection to the OWL servers is re-established.

The buffer is filled up based around the logging rate of the different devices:
  1. Electricity Transmitter:
    • 12 secs (5 per minute)
  2. Room / Tank Sensor:
    • 33 secs when in a heating period (2 per minute)
    • 5 secs for 1 minute after a button is pressed
    • 63 secs when in standby
    • 303 secs when away/holiday etc
  3. Relay Unit:
    • 30 secs
 
Example for Intuition-hw system with electricity monitor:
-------------
electricity + room sensor + tank sensor + relay unit = (5 + 2 + 2 + 2) = 11 logs per minute (assuming a 33 sec update on room sensor)
 
    12415 / 11 = 1128 / 60 = 18 hours of logging
 
 
Example for Intuition-c system without electricity monitor:
-------------
room sensor 2 logs per minute (assuming a 33 sec update on room sensor)
 
    12415 / 2 = 6206 / 60 = 103 hours of logging
 
 
Example for Intuition-hw system with electricity monitor and 2 heating zones:
-------------
electricity + (room sensor x 2) + tank sensor + relay unit = (5 + 4 + 2 + 2) = 13 logs per minute (assuming a 33 sec update on room sensor)
 
    12415 / 13 = 955 / 60 = 15 hours of logging